Connection documentation

Requirements

OLT

  • ZTE C300 / C320, ZXAN V2.1.0 (V1.2.x is also supported with limitations). Cards: GTGO, GTGH, GTGHK, SMXA, SCXN.
  • BDCOM P3xxx (EPON/GPON), V-SOL V1600: ONU monitoring and management; TR-069 depending on the ONU's capabilities.
  • Telnet (port 23) and SNMP v2c (161) enabled on the OLT management interface. A telnet user with configuration rights (privilege 15).
  • For instant events: SNMP traps to the hub (enabled from the panel with one button).

Network

  • A MikroTik with RouterOS 7 (WireGuard) in front of the OLT. RouterOS 6: OpenVPN, on request. Any other router with WireGuard: by instruction.
  • The OLT must be reachable from the MikroTik via its management IP (usually a separate management VLAN/subnet).
  • A Mgmt VLAN for ONUs with DHCP (Mgmt IP pool) for TR-069 and remote access to the ONU web interface. A route from that network to the ACS (via the tunnel or the internet).
  • Outgoing UDP 51820 from the MikroTik to the internet for WireGuard.

ONU

  • Any GPON ONU the OLT registers. To manage Wi-Fi/ports via OMCI, an ONU type on the OLT with the right set of ports (the platform picks it by model and can create types).
  • For TR-069: an ONU with a CWMP client; ZTE F6xx and Huawei HG8xxx work out of the box, on some OEM models TR-069 is enabled in the ONU web interface.